Powered by Ranger® Technology, the Yourgene® QS250 is optimised for use in Yourgene Health’s clinical NIPT workflows. Enriching fetal fraction through automated size selection of fragment lengths improves outcomes for NIPT patients by reducing both the cost of analysis, and the number of no-call tests.
The Yourgene® QS250, powered by Ranger® Technology, provides automated DNA electrophoresis for target enrichment in Yourgene’s clinical NIPT workflows, IONA®️ Nx NIPT Workflow and Sage™️ 32 NIPT Workflow.
These NIPT solutions apply a quantitative methodology to examine cell-free DNA (cfDNA) in order to measure the relative proportion of chromosomes, for example, chromosome 21, in a patient sample, to assess whether an excess or deficit of chromosomal material is present that is indicative of a fetal aneuploidy.
As cfDNA is comprised of both maternal and placental DNA, enriching fetal fraction through automated size selection of fragment lengths provides more of the DNA fragments we are looking for. This improves outcomes for NIPT patients by reducing the cost of analysis, reducing false positives/negatives and reducing the number of no-call tests due to too low a fetal fraction for analysis. Providing patients with confidence in their results.
Through Yourgene’s chosen library preparation methodology coupled with our QS250 platform and the patented Ranger technology, a relative enrichment of up to two-times the fetal DNA is achievable for our solutions:
The Yourgene® QS250 can integrate with automated robotics to provide a fully automated size selection and quality control workflow. As well the core size selection functionality, the instrument can be used to perform fragment length analysis and fluorescence assays for full NGS library integrity assessment and balancing prior to pooling. Making it a valuable addition to any laboratory.
| Parameter | Specification | Additional Information |
|---|---|---|
|
Allowable Size Range
|
50 - 500 bp*
|
|
|
Loading Capacity
|
2 μg
|
|
|
Size Selection Modes
|
Band Pass
|
Ranger® Technology enables different ways to define the boundaries of target ranges
|
|
Accuracy
|
>95%
|
Measured as the deviation between the specified target size and the size of the collected fraction
|
|
Reproducibility
|
>97%
|
Measured as 2X the standard deviation of the size of replicate samples
|
|
Min. Size Distribution as CV
|
<3.5%
|
Depends on reagent kit selection
|
|
No. of Samples / Run
|
12 (CGI-Format)
8 (SBS-Format) |
|
|
Run Time
|
45 minutes
|
Final volume influenced by pipetting technique
|
|
Extraction Sample Volume
|
150 μl
|
Dependent on run conditions, particularly the relationship between the target range and the extraction volume.
|
|
Intrinsic Recovery Efficiency
|
Average >70%
|
|
|
Weight
|
20.5 kg
|
|
|
Dimensions (W x D x H)
|
32.5 cm x 42.4 cm x 38.1 cm
|
|